SKU: DDRSM-21
Cena: 3.900.000,00 RSD
troškovi isporuke nisu uključeni
High Frequency Mobile Surgical X-ray System
Usage
Orthopedics: osteopathy, displaces, nailing.
Surgery: removing foreign body, cardiac catheter, implanting pace maker, interventional therapy, partial radiography, local photography, and other work.
PARAMETER |
SPECIFICATION |
||
Fluoroscopic Capacity |
Max rated capacity |
Tube Current 4mA, |
|
Tube Voltage 120kV |
|||
Automatic Fluoroscopy |
Tube Voltage:40kV~120kV Adjust Automatically |
||
Tube Current |
0.3mA~4mA set manually |
||
Manual Fluoroscopy |
Continuous Tube Voltage:40kV~120kV |
||
Continuous Tube Current |
0.3mA~4mA |
||
Pulse Fluoroscopy |
Continuous Tube Voltage 40kV~120kV |
||
Continuous Tube Current |
0.3mA~30mA |
||
Photography Capacity |
Max rated capacity |
5 KW |
|
Tube Voltage and Current Combination
|
40kV~49kV 1 ~180 mAs |
||
50kV~59kV 1 ~140 mAs |
|||
60kV~69kV 1 ~125 mAs |
|||
70kV~79kV 1 ~110 mAs |
|||
80kV~89kV 1 ~100 mAs |
|||
90kV~99kV 1 ~80 mAs |
|||
100kV~109kV 1 ~63 mAs |
|||
110kV~120kV 1 ~50 mAs |
|||
Plateholder Size |
200mm×250mm(8″×10″) or 250mm×300m(10″×12″) |
||
X-ray Tube |
X-ray Tube Special for High Frequency |
||
Fixed anode Dual focus |
large focus: 1.5, small focus: 0.3 (Advantage) |
||
Inverter Frequency: |
40KHz |
||
Thermal capacity: |
35KJ (47KHU) |
||
Video System |
Image Intensifier |
Image Intensifier made by TOSHIBA (9″,6″,4.5″) |
|
CCD Vidicon |
Ultralow light megapixel CCD camera imported from Japan |
||
Monitor |
23inch Horizontal 1280 lines and vertical 1024 lines, |
||
Bandwidth : |
48MHz, Image/sec : 75 grayscale: ≥ 11 Line pairs resolution: ≥ 1.2 LP / mm |
||
Integrated digital acquisition and processing system |
Registration: registration, medical records, Worklist Collection: Start collection; prepare video, reset, horizontal mirror, vertical mirror, window adjustment, magnifying glass, negative image Open silhouette, edge enhancement, recursive noise reduction Processing; four windows, nine windows, sharpening, horizontal mirror, vertical mirror, text annotation, length measurement report: save, preview, expert template Dicom features: Dicom browsing, web service |
||
Structure |
Directive wheel |
±90°revolution can freely change the moving direction of the unit |
|
Ascending & Descending Range of Pillar |
≥400mm |
||
C-arm |
Forward and Backward Movement: 200mm |
||
Revolution around Horizontal Axis |
±180° |
||
Revolution around Vertical Axis |
±15°( Advantage), better than others’ ±12.5°, easier to take special positions radiography) |
||
Slip on orbit |
120°(+90°~ 30°) |
||
Frame monitor rotation |
≥ 300 ° |
||
0615454040 Prodaja i Komercijala - Poručivanje telefonom
9h-20h, Poslovvni racun-Zber banka broj poslovnog racuna, RSD-285-2291050000499-50 EURO-285-201604000873537.
Kategorija: C- Arm medical Machine
Brend: Direktna Podrska
Kod proizvoda - SKU: DDRSM-21